Design a reinforced concrete (RC) short column with axial load
PROCEDURE
Configuration:
- Configure the parameters such as working load (KN), grade of concrete, grade of steel, unsupported length lx (m), unsupported length ly (m) and support conditions.
- Proceed to the next step by clicking on the next arrow.
- Calculate factored load (Pu), effective lengths lxeff and lyeff in mm. After three incorrect attempts, correct formula and value will be displayed.
- Proceed to the next step by clicking on the next arrow.
Calculations:
- Assume and enter the value of Asc within the range of 0.8% to 6% as per IS 456:2000, Clause 26.5.3.1 a. Values of Ag, Ac and Asc will be displayed.
- Select the type of column. Proceed to the next step by clicking on the next arrow.
- Enter the value of b/D ratio. After clicking on submit button, checks for short column and axially loaded column along with dimensions of column are displayed.
- Proceed to the next step by clicking on the next arrow.
- Enter the diameter of longitudinal bar which should be more than or equal to 12 mm as per IS 456:2000, Clause 26.5.3.1 d.
- Enter the number of bars. Enter the diameter of lateral ties to be provided. Enter the value of cover to be provided in mm.